Manufacturer or standards-body identification; product values do not apply to every form or condition.
Specific property examples
What distinguishes this material
Nitronic 50 / XM-19 has separate annealed and proprietary high-strength bar conditions. The bulletin distinguishes annealing temperature and bar diameter; its HS state is obtained by mill processing, not an interchangeable anneal.
Designation in this reference
Nitronic 50 / UNS S20910
Forms covered by the sources
Electralloy bar, forging-quality billet, ingot and master-alloy supply; other manufacturers supply additional forms.
States to distinguish or confirm
Annealed condition requires the actual annealing temperature and cooling method.
High-strength mill-processed bar is a separate condition; later hot work can change its strength.
Temperature and exposure
The example applies only to the bulletin’s 1-inch-diameter annealed bar at room temperature; it is typical data, not a purchase minimum.
Other search names in these sources
UNS S20910 · XM-19
Read the scope above: a source’s related product name is not a blanket interchangeability statement.
Property evidence for a stated condition
Read the complete example before using a number. Typical values are not guaranteed limits. Missing test conditions remain visible.
Specific source example
Nitronic 50 annealed 1-inch bar
Product / specimen
1 in (25.4 mm) diameter bar
Condition
Annealed at 2050°F (1121°C), water quenched
Test temperature / environment
Room temperature
Values apply to the example above
Property
Value
Meaning and method
Tensile strength
827 MPa
typical Producer bulletin Table 2; original value 120 ksi.
0.2% yield strength
414 MPa
typical 0.2% offset, Table 2; original value 60 ksi.
What product standard, edition and complete grade are on the material certificate?
What product form, section size and delivery/heat-treatment condition will be machined?
For machining, take the exact grade, supplied condition and measured hardness where applicable into the tool maker’s application data. A generic material-family speed is not a substitute for an operation and tool-specific recommendation.
Source identity, a named product example and a supplied-batch certificate are different evidence. Cross-standard similarity does not approve substitution.
Corrections from the previous article
Remove unconditional 95 HRB/760 MPa values; do not use Nitronic 60 galling results as Nitronic 50 evidence.
Withdraw the legacy generic hardness (95 HRB) and tensile-strength (760 MPa (110 ksi)) pair: the old page does not establish a matching product, heat treatment, section and test source.
Remove the unsupported cutting-speed table and machinability percentage; select tooling only after the actual material condition is known.