Stainless steel
AISI 302
Manufacturer or standards-body identification; product values do not apply to every form or condition.
Identity / state reference
What distinguishes this material
Alleima distinguishes its 12R10 and remelted 12R10 HV wire products. A wire brand or 302VM label cannot be applied to every Type 302 heat.
- Designation in this reference
- Type 302 / UNS S30200
- Forms covered by the sources
- Alleima medical wire example.
- States to distinguish or confirm
- Specify wire temper, tensile class and any vacuum-remelting requirement.
- Temperature and exposure
- No universal service-temperature limit or room-temperature property set is assigned. Use the cited product document and the purchase certificate.
Other search names in these sources
UNS S30200
Read the scope above: a source’s related product name is not a blanket interchangeability statement.
Property evidence for a stated condition
No condition-specific numerical table is reproduced here
The linked sources establish the identity and the stated product/state scope. Obtain the row for your actual form, section, treatment and test conditions before adopting strength, hardness or a thermal limit.
Resolve these conditions next
- What product standard, edition and complete grade are on the material certificate?
- What product form, section size and delivery/heat-treatment condition will be machined?
For machining, take the exact grade, supplied condition and measured hardness where applicable into the tool maker’s application data. A generic material-family speed is not a substitute for an operation and tool-specific recommendation.
Sources and what they establish
Reviewed 23 October 2026. A source’s publication date and the review date are different. The scope below identifies the fields checked.
Alleima 12R10 / 12R10 HV medical wire
Product-specific 302/302VM wire identities and HV remelting; not all 302 bar or sheet.
Alleima 12R10 / 12R10 HV medical wire ↗Carpenter Technology product line card
Exact alloy names and UNS identities; branded variants such as Project 70+ are not universal property data for the base grade.
Carpenter Technology product line card ↗Source identity, a named product example and a supplied-batch certificate are different evidence. Cross-standard similarity does not approve substitution.
Corrections from the previous article
- Remove automatic 302/304V/302HQ interchangeability; the latter designations are product-specific or separate alloys.
- Withdraw the legacy generic hardness (88 HRB) and tensile-strength (620 MPa (90 ksi)) pair: the old page does not establish a matching product, heat treatment, section and test source.
- Remove the unsupported cutting-speed table and machinability percentage; select tooling only after the actual material condition is known.
Other references in Stainless steel
Related references, not equivalent substitutes.